Start with the simple things: the thermostat set to cool and below room temperature, a clean filter, open vents, and a breaker that has not tripped. If those are fine, ice on the coil or a weak outdoor unit points to a repair. Call the number on this page to be connected with a local AC company in Rhome.

When the thermostat is the culprit
Sometimes the thermostat itself has failed or lost its wiring connection, and it never signals the AC to start. Signs include a blank screen with fresh batteries, a display that stays on but never clicks, or a reading that does not match the room. A technician can test the signal quickly and tell whether it needs replacing.
Weak air in some rooms only
| Symptom | Possible cause |
|---|---|
| One room warm | Closed or blocked vent, duct problem |
| Whole upstairs warm | Airflow imbalance or a struggling system |
| Weak air everywhere | Filter, blower or coil restriction |
Matching the pattern to the cause saves a guessing game, and it gives the technician a head start on the diagnosis when you call.
Homes on acreage often have equipment far from the road and a longer trip to a supply house, so a clear symptom description helps the company bring the right parts.
Why ice means low air or low charge
A coil only freezes when it gets too cold, and that happens when not enough warm air crosses it or the refrigerant level is off. The first cause is easy to fix. The second means a leak somewhere in the sealed system. Either way, repeated freezing needs a technician and not another thaw.
Step four: power and the outdoor unit
Check the breaker for the outdoor unit and the one for the air handler; if either has tripped, reset it once. Make sure the outdoor disconnect is on. Then look at the condenser: the fan should spin, and the coil should be clear of grass, leaves and cottonwood fluff.
Step five: refrigerant and the compressor
If the thermostat, filter, coil and power all check out and the air is still warm or only slightly cool, the system may be low on refrigerant or have a weak compressor. Refrigerant does not get used up; low charge means a leak. Only a certified technician can find and repair it.
Before work starts in Rhome
Before you approve the work, check the company's ACR contractor license with TDLR; the state agency also takes complaints about AC contractors.
Federal rules require EPA 608 certification for technicians who service equipment containing refrigerant, which covers most AC repairs beyond filters and breakers.
Replacement and new installation work can require a permit, and Rhome Permitting Department is where that's handled for Rhome addresses.
Power outages here go to Oncor at 888-313-4747, not to your retail electric provider. If the AC and the lights are both out, check that first.
Companies that take calls here usually also work in Fort Worth, Saginaw and Northlake.
AC Not Cooling questions in Rhome
What does it mean if there is ice on my AC?
Can a dirty filter really stop my AC from cooling?
My AC blows warm air but the outdoor unit is running. Why?
Should I add refrigerant myself?