An AC that runs but does not cool is usually a thermostat setting, a clogged filter, a frozen coil, a tripped breaker or a refrigerant problem, in roughly that order of how easy they are to check. The first four you can look at safely; refrigerant always needs a technician. Call the number on this page to be connected with a local AC company in Northlake.

Step one: the thermostat
Confirm the thermostat is set to cool, not heat or fan only, and that the target is a few degrees below the room reading. Dead batteries or a blank display can stop the system entirely. A programmable or smart thermostat may also be following a schedule you forgot about, so check for a hold or an away mode.
Airflow checklist
- Filter clean and installed the right way round
- Return grille not blocked or caked with dust
- Supply vents open in every room
- Blower audibly running at the air handler
- No crushed or disconnected flex duct you can see
Fix what you can reach safely, then recheck the air coming out.
Homes on acreage often have equipment far from the road and a longer trip to a supply house, so a clear symptom description helps the company bring the right parts.
Do not chip the ice
It is tempting to scrape ice off the coil or the line, but the fins and tubing are delicate, and a puncture turns a no-cool call into a refrigerant leak. Let it melt on its own with the fan running. Tell the company you saw ice and how long it took to appear.
After a storm or an outage
Brief outages and surges are hard on the capacitor, contactor and control board. If the AC was fine yesterday and silent today, check for a tripped breaker, then the thermostat display. These parts are common failures after weather events, and a technician can test them quickly without much disruption.
Useful local contacts for Northlake
Texas requires anyone contracting for air conditioning and refrigeration work to hold an ACR contractor license from the Texas Department of Licensing and Regulation (TDLR). Ask for the license number and check it on TDLR's license search.
Anyone who opens a refrigerant circuit has to be EPA Section 608 certified, and venting refrigerant is not allowed, so leak work and recharges belong with a certified technician.
Northlake Building Inspections is the office for building and mechanical permits in Northlake; ask the contractor whether your job needs one.
Oncor delivers electricity in Northlake and handles outages at 888-313-4747; your bill and plan come from whichever retail provider you signed with.
Nearby, the same kind of help is available in Fort Worth, Justin and Trophy Club.
Why topping off is not a cure
Adding refrigerant to a leaking system is a temporary patch at best. The leak remains, the charge drains again, and the compressor can be damaged by running low. A proper repair locates the leak, fixes it, then recharges. Ask the technician to explain which approach they recommend and why.
AC Not Cooling questions in Northlake
Why is my AC running but not cooling?
Why is cool air coming from only some rooms?
What should I tell the company?
Could a power outage have caused this?
More AC and heating services in Northlake
AC Not Cooling nearby
Helpful guides
Sources
Last updated: