A humming outdoor unit with a fan that does not turn usually points to a weak or failed capacitor, a worn fan motor or a bad contactor. These parts take a beating in North Texas heat, and a technician can test them quickly on site. Call the number on this page to be connected with a local AC company in Keene.

Signs the outdoor unit needs help
Stand well back from the condenser and listen. A steady hum with a motionless fan, a click that repeats, or a fan that only turns after a push are all warning signs. Indoors, you may notice warm air, a system that runs for hours or one that shuts off on its own.
Dirty coils make parts work harder
Cottonwood fluff, grass clippings and dust packed into the outdoor coil raise pressures and heat. The fan and capacitor have to work harder, so a neglected unit tends to lose these parts earlier than a clean one.
That is why a coil rinse is part of most good tune-ups.
On acreage, the outdoor unit may be a long walk from the house. Listen for the fan when the system is running, and call a local AC company if you hear humming without the fan moving.
Damage from running a failed fan
If the unit kept running with a dead fan, the compressor may have overheated. That can raise the final cost, so shutting the system off at the thermostat when you notice the problem is worth doing.
Ask whether the compressor was checked after the fan problem.
Fan motor and blade inspection
The technician spins the blade by hand with power off, listens for rough bearings and checks the motor's draw. A loose blade, a bent shaft or a hot motor housing tells them whether the motor needs replacement.
They may also look for oil leaks.
When to shut the system off
If the outdoor fan is stopped but the unit is humming, turn the thermostat to off. Running a compressor without a working fan can lead to overheating and a much bigger repair. Then call and describe what you heard.
Never put anything into the unit while it is on.
Permits, power and gas in Keene
Texas requires anyone contracting for air conditioning and refrigeration work to hold an ACR contractor license from the Texas Department of Licensing and Regulation (TDLR). Ask for the license number and check it on TDLR's license search.
Anyone who opens a refrigerant circuit has to be EPA Section 608 certified, and venting refrigerant is not allowed, so leak work and recharges belong with a certified technician.
Replacement and new installation work can require a permit, and the city's building department is where that's handled for Keene addresses.
Power outages here go to Oncor at 888-313-4747, not to your retail electric provider. If the AC and the lights are both out, check that first.
Calls from Keene are often matched with companies that also cover Fort Worth, Cleburne and Joshua.
AC Capacitor & Fan Motor Repair questions in Keene
What does a capacitor do in an air conditioner?
How long does a capacitor last?
Is it safe to run the AC if the outdoor fan won't turn?
Do power surges damage AC capacitors?
More AC and heating services in Keene
AC Capacitor & Fan Motor Repair nearby
Helpful guides
Sources
Last updated: